Skip to main content

L8X · WATER HEATER POWER CONTROL

LANBON version

Power on. On your schedule.

A glass touch panel for a compatible storage water heater. Double-pole 16 A power switching, app control and scheduling, with EU/US formats in white or black.

L8X-HB-W · 86 × 86 mm · White · Double-pole 16 A

L8X-HB-W · 86 × 86 mm · White · Double-pole 16 A supplied product view

Double-pole 16 A

Power switching for a compatible single-phase resistive storage water heater.

Your schedule

Use the app to plan power on/off around your routine.

Glass touch panel

Key backlighting indicates off, 30-minute, 60-minute and always-on states. No LCD.

Three network versions

LANBON, Tuya Wi-Fi or Tuya zigbee with the shared selector.

BEFORE INSTALLATION

Match the heater, circuit and protection.

Have a qualified electrician confirm the actual heater load, installation and protective devices. This product switches power; the heater retains its own thermostat and safety functions.

01
Power and neutral

AC 100–250V · 50/60Hz · Neutral required

02
Current and load

Double-pole 16 A. Compatible single-phase resistive storage water heater, within 16 A at the actual supply voltage.

03
Control boundary

Power on/off only; no water-temperature sensing, setting or adjustment.

04
Required protection

Keep the required upstream circuit/leakage protection and heater safety devices. No independent leakage, overload, overcurrent, short-circuit, overheat or dry-heating protection.

05
Wall box and conductors

Greater than 38 mm usable depth plus wiring space; 14–12 AWG for the double-pole version.

06
Network

Follow setup requirements for the selected networking version.

KEY BACKLIGHT · TIMER STATUS

One key. Four power and timer states.

Press the centre key to cycle through 30 minutes, 60 minutes, always on and off. The key backlight indicates the selected timer state.

L8X-HB-W · Original product key · interactive illustration

CURRENT STATE

Off

Steady green

Heater power is off. The green key backlight stays on.

Key backlight and timer reference
PressPower / timer stateKey backlightAt timer end
Off / initialOffSteady greenNo timer
First press30-minute timerSlow blue flash: 1 s on / 1 s off30 min: off, steady green
Second press60-minute timerFast purple flash: 0.5 s on / 0.5 s off60 min: off, steady green
Third pressAlways onSteady redNo timer
Press againOffSteady greenNo timer

The original product photo supplies the exact key outline and shower icon. When the backlight flashes off, the gray key marking stays visible. Interactive illustration, not a connected heater. “Preview timer expiry” skips the illustration countdown; actual timers are 30 or 60 minutes. Power on does not indicate temperature or hot-water readiness. Reduced-motion settings show steady colours with the flash pattern described in text.

EVERYDAY POWER CONTROL

Plan power. Let the heater manage heating.

At the wall

Cycle the centre key through 30 minutes, 60 minutes, always on and off.

From your phone

Use the app for your selected networking version. Remote access requires internet and available services.

Schedules and timers

Set power on/off times in the app. Timer durations are not heating-time or water-temperature guarantees.

Keep the right safeguards

The switch does not replace the heater thermostat, dry-heating protection or upstream electrical protection. Confirm all of them as part of the installation.

LANBON APP

Keep power control close.

The supplied LANBON screens show heater power control, timer shortcuts and schedules. Screens are examples, not a live connection. This model does not support energy monitoring or temperature control.

Power on/offTimersSchedules
Supplied L8X-HB LANBON power and timer screen
Supplied L8X-HB LANBON schedule screen

LANBON · L8X · WI-FI MESH

Switches form their own network.

Compatible L8X series switches share a network without a dedicated gateway. Configure the first switch near the router as the master, then configure the remaining switches.

Control through LANBON Smart Living. Remote features still require a router, internet and available services. Switch Mesh does not extend Wi-Fi for phones or computers.

MODEL & INSTALLATION

Technical specifications

Match the exact installed model and its label.

Key specifications

Model
L8X-HB-W
Panel dimensions
86 × 86 mm
Power supply
AC 100–250V · 50/60Hz
Switching type
Double-pole
Rated current
16 A
Load type
Compatible single-phase resistive storage water heater
Wall-box depth
>38 mm
Terminal torque
0.5 N·m

The front drawing is an enclosure example, not the selected heater-key layout. Its 32 mm dimension does not establish sufficient usable wall-box depth. Confirm the installed model, circuit and current firmware power-restoration behavior.

QUALIFIED INSTALLATION

Confirm the complete heater circuit.

  1. Isolate the supply. A qualified electrician confirms the actual double-pole 16 A model, neutral and earthing requirements.
  2. Check the storage heater is a compatible single-phase resistive load within 16 A at the actual supply voltage. Do not use for instantaneous, gas or inductive loads.
  3. Use current exact-model wiring instructions. Confirm conductor size, terminal torque, protective devices and sufficient wall-box space.
  4. Secure the panel before restoring power. Verify on/off and schedules while retaining the heater thermostat and safety systems.
Ask about installation

DEVICE & APP EXAMPLES

See the supplied operation examples.

Heater power-control illustration

Supplied animated illustration, not filmed hardware or a heating-performance test. The confirmed key-backlight and timer states are shown in the interactive module above.

LANBON App demonstration

Supplied LANBON App example, not a live connection or a water-temperature reading.

DOCUMENTS & SUPPORT

Documents for your panel format.

Contact support for current double-pole 16 A wiring and operating instructions, heater compatibility, firmware behavior, certification and destination supply.

Get model-specific support